The Building

Building pre-intervention

Building pre-intervention: AlteSchäfflerei_Pre-Intervention_FraunhoferIBP_1.jpg
Building pre-intervention: AlteSchäfflerei_Pre-Intervention_FraunhoferIBP_2.jpg

Building post-intervention

Building post-intervention: AlteSchäfflerei_Post-Intervention_FraunhoferIBP.jpg

Alte Schäfflerei

The Alte Schäfflerei, built around 1760, is situated in the former craftsmen’s courtyard of the listed building complex. Since 2010, the Fraunhofer Institute for Building Physics IBP and the Fraunhofer Information Centre for Space and Construction IRB have established a centre there dedicated to the energy-efficient renovation of old buildings and the preservation of historic buildings.

More Details

The Solution

Solution pre-intervention

Solution pre-intervention: AlteSchäfflerei_Solution_Pre-Intervention_FraunhoferIBP_1.jpg
Solution pre-intervention: AlteSchäfflerei_Solution_Pre-Intervention_FraunhoferIBP_2.png

Solution post-intervention

Solution post-intervention: AlteSchäfflerei_Solution_Post-Intervention_FraunhoferIBP_1.jpg
Solution post-intervention: AlteSchäfflerei_Solution_Post-Intervention_FraunhoferIBP_2.jpg
Solution post-intervention: AlteSchäfflerei_Solution_Post-Intervention_FraunhoferIBP_3.png
What is the Solution?

Fitting of an additional double-glazed window unit with thermal insulation glazing with a glazing distance of 13 cm.

Why Does it work?

The second layer provides significantly better thermal insulation.

PROS
  • significantly improvement of the U-value and the airtightness
  • maintain the historic window
CONS
  • change of the appearance, because of the second window layer
Window Type before retrofit
Casement Window
Window glass type
Double low-e
Window frame material
Wood
Window position
Outside
Shading
No shading
Health issue
information not available
Installation Method
information not available
Moisture Management and Technical Compatibility
Measurements were carried out to determine the U-values.
Airtightness
information not available

Before retrofit

After retrofit

Before retrofit
Uw-Value
4.5
After retrofit
Uw-Value
inner: 1,75 whole: 1,4
Before retrofit
Ug-Value
4.4
After retrofit
Ug-Value
inner window: 1,3
Before retrofit
g-Solar factor
information not available
After retrofit
g-Solar factor
information not available

Assessment

Window type
Double window
Frame material
Timber
Aesthetic impact
Impact on the appearance only from the inside
Frame improvement
Yes
Glazing improvement
No
Additional glazing
Yes
Airtightness improvement
Yes
Window U-value
1 < U <= 2
Shading
No
Circular approach
Yes
Circular approach (Additional info)
Maintainence of the whole window, addition of extra layer.
Investment cost
High

Location

Benediktbeuern, Germany - 620m
Climatic Zone:Cfb