WallMagasinet, Varvsstaden, Malmö - Internal Insulation - Lime-based insulating plaster - 50 mmMagasinet, Varvsstaden, Malmö Details
Magasinet i Varvsstaden - Expanded polystyrene insulation - 200 mm
Solution Year
2020
Building Age
1900-1944
Listed Building
No
Conservation Area
Yes
Documenting Institution
STRESS
Location
Malmö, Sweden - 2m
Building Type
Offices
Structure
Concrete frame
The Building
Magasinet i Varvsstaden
Västra hamnen is one of Malmö's development areas where the shipyard's old industrial site is being transformed into a new neighbourhood with both businesses and housing. The warehouse building is part of the oldest group of buildings in Västra hamnen and in 2020 an extensive renovation was carried out to transform the building from its original use as a warehouse and model making to an office building. The warehouse has a rectangular shape and is built on three floors. A staircase tower on the southern facade extends above the roof slope and is crowned by a gable roof. The facades of the buildings are made of red brick with decorations in lime sandstone. The arched cast-iron windows are arranged in groups of three on the two upper floors and in groups of two on the ground floor. On the ground floor there are gates, doors and some windows painted with green colour and mainly made of wood. In the building's interior, the load-bearing concrete frame is visible, with columns and beams. The floors are generally spacious, open spaces with poured concrete floors. The building has a high architectural and cultural-historical value.
More DetailsThe Solution
What is the Solution?
The solution consist of the demolition of existing floors on the ground in order to add a new layer of insulation on the existing concrete slab. The insulation layer is made of 200mm thick cellular plastic foam. The insulation is installed up to a small distance from the walls in order to have a better energy performance suitable to the new function. The original floor has not been retrieved. A new macadam floor was laid in its place.
Why Does it work?
The existing floor was not considered historically valuable so it was possible to be removed to install the insulation.
PROS
- The U-value of the floor is improved.
- Improvement against moisture
- Simplicity of installation
CONS
- it was necessary to remove the existing floor that it was not possible to preserve
Insulation material
Expended Polystyrene (EPS)
Insulation thickness
200
Thermal conductivity
0.024
Health issue
information not available
Technical drawings
Additional documentation
Installation Method
Existing floors on the ground are removed and insulation is added where possible. This means that the floors will be insulated (200mm foam) up to a small distance from the walls.
Moisture Management and Technical Compatibility
information not available
Airtightness
information not available
Before retrofit
After retrofit
Before retrofit
Floor thickness
160
After retrofit
Floor thickness
510
Before retrofit
Floor build-up
Slab_ Concrete_[160mm]
After retrofit
Floor build-up
Slab_Concrete_[160mm], Insulation cellular plastic_[200mm], Finish_Macadam_[150mm]
Before retrofit
U-value
4
After retrofit
U-value
0.17
Assessment
Floor type
Slab
Insulaiton position
Above the load bearing structure
Flooring maintained
No
Floor U-value
U <=0.25
Insulation type
Synthetic
Circular approach
No
Reversibility
No
Investment cost
Medium Low
Location
Malmö, Sweden - 2m
Climatic Zone:Cfb